README: maxView Storage Manager & ARCCONF Command Line Utility

Microsemi Adaptec maxView Storage Manager
Microsemi Adaptec Command Line Interface Utility (ARCCONF)

as of April 10, 2018
--------------------------------------------------------------------
Please check the product website for newer versions of this file to
ensure you are reviewing the latest information.

This file contains important information about issues and errata that were
discovered after completion of the standard product documentation.

In the case of conflict between various parts of the documentation set, 
this file contains the most current information.

--------------------------------------------------------------------

Table of Contents

Chapter 1. New Features of this Release 	 

Chapter 2. Software Versions and Documentation 	 
2.1 Utility Software 	 
2.2 Documentation 	 
    2.2.1 Series 8 Product Documentation 	 
    2.2.2 HBA 1000 Series Product Documentation 	 
    2.2.3 SmartIOC Product Documentation 	 

Chapter 3. Installation Notes 	 
3.1 Installation and Setup 	 
3.2 Supported Operating Systems 	 
    3.2.1 Series 8 Controllers 	 
    3.2.2 Smart Family Controllers 	 
3.3 General Setup Notes 	 
3.4 Remote Access 	 
3.5 Windows 8 Setup 	 
3.6 SLES Setup 	 
3.7 Ubuntu Setup 	 
3.8 XenServer Guest OS Setup
3.9 Installing ARCCONF on PowerPC
3.10 Bootable USB Image Security Warnings 	 
3.11 RAW Device Setup (Series 8 Only) 	 
3.12 maxView Plugin for VMware vSphere Web Client 	 

Chapter 4. Known Limitations 	 
4.1 Global Limitations 	 
     4.1.1 Dual-Controller Systems 	 
     4.1.2 Email Notifications 	 
     4.1.3 SGPIO Enclosures 	 
     4.1.4 Non-RAID Mode Controllers 	 
     4.1.5 Browser Issues 	 
     4.1.6 Remote System Access on Linux and Windows 	 
     4.1.7 RAID 10 Segment Order 	 
     4.1.8 RAID 10 Rebuild Order 	 
     4.1.9 Locate Logical Drive Blink LED 	 
     4.1.10 ARCCONF Backward Compatibility 	 
     4.1.11 Updating Hard Disk Firmware on VMware Guest OS 	 
     4.1.12 Hot Swap Issues on VMware CentOS Guest OS 	 
     4.1.13 Enclosure Status Reporting 	 
     4.1.14 PHY Status on Enclosure Backplanes 	 
     4.1.15 Special Characters in Logical Device Names 	 
     4.1.16 Speaker Status on SuperMicro SAS2X28 Enclosures 	 
     4.1.17 Online Help Issues 	 
     4.1.18 Broadcasting Alerts About Status and Activity 	 
     4.1.19 User-Specified Archive Path 	 
     4.1.20 Clear Configuration Status After Re-Insertion 	 
     4.1.21 Configuration Changes in Device Manager 	 
4.2 Limitations for Series 8 Controllers 	 
     4.2.1 RAID-Level Migrations 	 
     4.2.2 maxCache Device Migration 	 
     4.2.3 ARCCONF maxCache Device Size Issue 	 
     4.2.4 Power Management Issues 	 
     4.2.5 Verify/Verify with Fix 	 
     4.2.6 ATA Secure Erase	 
     4.2.7 Simple Volume Support 	 
     4.2.8 Auto-Volume Support 	 
     4.2.9 Hot-Removing Disk Drives on Xenserver Guest OS 	 
     4.2.10 Viewing Logical Drive Details After Re-Insertion
	 4.2.11 VMware ESXi 6.X CIM Service Errors
	 4.2.12 Proxy/Firewall Connection Issues
4.3 Limitations for Smart Family Controllers 	 
     4.3.1 SES Passthrough Commands to Expanders 	 
     4.3.2 Firmware Upgrade Issues 	 
     4.3.3 Mount Point Information with MPIO Support 	 
     4.3.4 Locate Physical Disk LED Behavior
	 4.3.5 Help Button Leads to Empty Login Page	
	 4.3.6 Firefox Browswer Crashes While Uploading Firmware
	 4.3.7 Backspace Recognized As Input Character
	 4.3.8 maxView Login Page Not Displayed After maxView Repair
	 4.3.9 VMware SFCB CIMMOM Causes Slowdown
	 4.3.10 Remote ARCCONF Command Delays
	 4.3.11 Locked ESXi User Account
	 4.3.12 Browser Automatically Fills Username and Password Fields
	 4.3.13 Expanded Logical Devices Not Initiated by Firmware
--------------------------------------------------------------------

Chapter 1. New Features of this Release

* Added new features:
	* Support for maxCrypto Controller-Based Encryption on the Microsemi Adaptec SmartRAID 3162-8i /e controller
	* Support for PowerPC platforms running RHEL and Ubuntu on SmartIOC 2000 and HBA 1000 controllers
	* Miscellaneous UI changes/enhancements.
	
* Bug fixes (see the Release Notes for a complete list)

--------------------------------------------------------------------

Chapter 2. Software Versions and Documentation

2.1. Utility Software

* Microsemi Adaptec(r) maxView Storage Manager Version 2.06.00 (B23167)
* Microsemi Adaptec(r) ARCCONF Command Line Interface Utility Version 2.06.00 (B23167)

2.2. Documentation

2.2.1 Series 8 Product Documentation

PDF Format
* maxView Storage Manager User's Guide for Microsemi Adaptec ARC-Family Controllers
* Microsemi Adaptec RAID Controller Command Line Utility User's Guide

HTML and Text Format
* maxView Storage Manager Online Help
* maxView Storage Manager/ARCCONF README.TXT file

2.2.2 HBA 1000 Series Product Documentation

PDF:
* maxView Storage Manager User's Guide for Microsemi Smart-Family Controllers
* Microsemi Adaptec HBA 1000 Series Command Line Utility User's Guide

HTML and Text Format:
* maxView Storage Manager for Smart-Family Controllers Online Help
* maxView Storage Manager/ARCCONF README.TXT file

2.2.3 SmartIOC Product Documentation

PDF:
* maxView Storage Manager User's Guide for Microsemi Smart-Family Controllers
* Microsemi SmartIOC 2000 Command Line Utility User's Guide

HTML and Text Format:
* maxView Storage Manager for Microsemi Smart-Family Controllers Online Help
* maxView Storage Manager/ARCCONF README.TXT file

--------------------------------------------------------------------

Chapter 3. Installation Notes

3.1. Installation and Setup
Refer to your product documentation for the installation and setup details:
* Your product Installation and User's Guide contains complete installation 
  information for your product's drivers.
* The maxView Storage Manager User's Guide for your product contains 
  installation information for the maxView Storage Manager software.
* The Command Line Utility User's Guide for your product contains complete 
  installation information for ARCCONF.

3.2 Supported Operating Systems

Notes:

1. maxView Storage Manager and ARCCONF Command Line Utility are supported on 
   64-bit operating systems only.
2. The Boot USB (offline or pre-boot) for ARCCONF and maxView Storage Manager 
   is supported on Linux.

3.2.1 Series 8 Controllers

Microsoft Windows
* Microsoft(r) Windows(r) Server 2016 RS1 (64-bit)
* Microsoft(r) Windows(r) Server 2012 (64-bit)
* Microsoft(r) Windows(r) Server 2012 R2 (64-bit)
* Microsoft(r) Windows(r) Server 2008 R2 SP1 (64-bit)
* Microsoft(r) Windows(r) 10 RS3 (64-bit)
* Microsoft(r) Windows(r) 8.1, 8 (64-bit)
* Microsoft(r) Windows(r) 7 (64-bit)

Linux for x64
* Red Hat(r) Enterprise Linux/CentOS 7.4 (64-bit)
* Red Hat(r) Enterprise Linux/CentOS 7.3 (64-bit)
* Red Hat(r) Enterprise Linux/CentOS 6.9 (64-bit)
* Red Hat(r) Enterprise Linux/CentOS 6.8 (64-bit)
* SuSE Linux Enterprise Server 12 SP3 (64-bit)
* SuSE Linux Enterprise Server 12 SP2 (64-bit)
* SuSE Linux Enterprise Server 11 SP4 (64-bit)
* SuSE Linux Enterprise Server 11 SP3 (64-bit)
* Ubuntu Linux 16.04.3 (64-bit)
* Ubuntu Linux 14.04.5 (64-bit)
* Oracle Linux 7.2 (64-bit)
* Oracle Linux 6.8 with UEK R4U4, UEK R3U7 (64-bit)

Linux on PowerPC
* Red Hat(r) Enterprise Linux 7.2 (64-bit)
* SuSE Linux Enterprise Server 12 SP1 (64-bit)
* Ubuntu Linux 16.04, 14.04.4 (64-bit)
* PowerKVM 3.1.0.1 (64-bit)

Virtual OS Environments
* VMware vSphere 6.7 (64-bit)
* VMware vSphere 6.5 U1 (64-bit)
* VMware vSphere 2016 (6.5) (64-bit)
* VMware vSphere 6.0 U3, U2 (64-bit)
* Citrix XenServer 7.1 (64-bit)
* Microsoft Hyper-V (64-bit)
Note: Hyper-V runs as a service on the Windows host OS and does not require a separate driver.

3.2.2 Smart Family Controllers

Microsoft Windows
* Microsoft(r) Windows(r) Server 2016 RS1 (64-bit)
* Microsoft(r) Windows(r) Server 2012 (64-bit)
* Microsoft(r) Windows(r) Server 2012 R2 (64-bit)
* Microsoft(r) Windows(r) Server 2008 R2 SP1 (64-bit)
* Microsoft(r) Windows(r) 10 (64-bit)
* Microsoft(r) Windows(r) 8.1, 8 (64-bit)
* Microsoft(r) Windows(r) 7 (64-bit)

Linux for x86/x64
* Red Hat(r) Enterprise Linux/CentOS 7.5, 7.4, 7.3, 7.2 (64-bit)
* Red Hat(r) Enterprise Linux/CentOS 6.9, 6.8, 6.7 (64-bit)
* SuSE Linux Enterprise Server 12 SP3, SP2, SP1 (64-bit)
* SuSE Linux Enterprise Server 11 SP4, SP3 (64-bit)
* Ubuntu Linux 16.04.4, 16.04.3, 16.04.01 (LTS) (64-bit)
* Ubuntu Linux 14.04.05 (LTS) (64-bit)
* Oracle Linux 7.2 UEK R4U2, UEK R3U7 (64-bit)
* Oracle Linux 6.8 UEK R4U2, UEK R3U7 (64-bit)

Virtual OS Environments
* VMware ESXi 6.7 (64-bit)
* VMware vSphere 6.0 U2, 6.0 (64-bit)
* VMware vSphere 2016 (6.5) (64-bit)
* VMware vSphere 2016 U2 (64-bit)
* Citrix XenServer 7.1, 7.0 (64-bit)

3.3 General Setup Notes
* maxView Storage Manager is not backwards-compatible with Series 5 and older Adaptec controller models.
* maxView Storage Manager and legacy Adaptec Storage Manager (ASM) cannot coexist on the same system.
* For Series 8 controllers:
   * maxView Storage Manager is not supported on FreeBSD. Use ARCCONF to create and manage arrays.

3.4 Remote Access
maxView Storage Manager requires the following range of ports to be open for 
remote access:
* 34570-34580 (TCP)
* 34570 (UDP)
* 34577-34580 (UDP)

3.5 Windows 8 Setup
To log in and use maxView Storage Manager on a Windows 8 system, you must 
create a local user account; you cannot use your MS Live account. To create a 
local user account:
1. Log into your MS Live account.
2. Select Settings->Change PC Settings->Users->Switch to Local user.
3. Provide account details.
4. Start maxView Storage Manager and log in with your local user account 
   credentials.

3.6 SLES Setup
To avoid a problem with launching maxView Storage Manager on SLES 11 or SLES 
12 x64 systems with DHCP enabled, ensure that the /etc/hosts file maps the 
server IP address to a valid host name; it is not sufficient to map the IP 
address to 'localhost'.

3.7 Ubuntu Setup
* To avoid a maxView Login failure on Ubuntu systems, you must ensure that the 
  root user account is enabled. (It is disabled, by default, on Ubuntu 14.04 
  and later because no password is set.)
  For example: sudo bash; sudo passwd root
* When upgrading maxView Storage Manager on an existing Ubuntu Linux x64 
  installation, you must enable the upgrade switch before installing the 
  maxView .deb package:
  
  export maxView_Upgrade=true
  dpkg -i StorMan-*.deb

  To uninstall maxView after the upgrade:
  
  export maxView_Upgrade=false
  dpkg -r storman
  
3.8 XenServer Guest OS Setup
To avoid an operating problem with maxView Storage Manager or ARCCONF on a XenServer Guest OS,
you must disable all LAN adapters in the Guest OS which are not connected to the network before
installing the maxView or ARCCONF software.

3.9 Installing ARCCONF on PowerPC

* Installing ARCCONF on PowerPC:
	* Installing on RHEL PowerPC 64-bit
	    rpm -i Arcconf-2.02-xxxxx.ppc64le.rpm
	* Installing on Ubuntu PowerPC 64-bit
	    dpkg -i Arcconf-2.02-xxxxx.ppc64el.deb
	* Installing on SLES PowerPC 64-bit
		rpm -i Arcconf-2.02-xxxxx.ppc64le.rpm
* Installing ARCCONF in Petitboot:
	* Extract package arcconf-2.02-xxxxx.tar.xz in the folder of your choice.
	
Where xxxxx is the installer version.		

3.10 Bootable USB Image Security Warnings
When running maxView Storage Manager from the bootable USB image, you may be 
prompted with one or more with security warnings before maxView launches. In 
each case, acknowledge the warning and continue.

The bootable USB needs root permission. To do this, execute the sudo -i command before executing
ARCCONF commands from the terminal.

3.11 RAW Device Setup (Series Only)
On Adaptec Series 8 controllers, a RAW Pass Through 
device is analogous to a JBOD, supported by Adaptec Series 8 controllers and 
older. Any drive without Adaptec RAID metadata is exposed to the OS as a RAW 
Pass Through device. To remove the Adaptec metadata and convert the drive to a 
RAW device, use the Uninitialize command in maxView Storage Manager; any 
existing data on the drive is destroyed. (You can also run uninit from the 
BIOS or ARCCONF.) For more information about working with RAW devices, see 
'controller modes' in the CLI User's Guide, and BIOS 'general settings' in the 
RAID Controller Installation and User's Guide.

3.12 maxView Plugin for VMware vSphere Web Client
The maxView Plugin for VMware vSphere Web Client is supported on VMware 6.0 
and 6.5.

--------------------------------------------------------------------

Chapter 4. Known Limitations

4.1 Global Limitations

4.1.1 Dual-Controller Systems
In dual-controller systems, the controller order in maxView Storage Manager 
and the BIOS differs. Example: with an Adaptec 72405 and 7805 installed, the 
BIOS reports the 72405 as controller 1 and the 7805 as controller 2; in the 
GUI, the controller order is reversed.

4.1.2 Email Notifications
On Linux systems, we recommend adding the SMTP host name and the system IP 
address, to the /etc/hosts file. Doing so ensures that email notifications 
will succeed if you specify the email server in maxView Storage Manager by 
host name. Otherwise, email notifications (including test messages) may fail 
if the DNS is unable to resolve the host name.
WORKAROUND: Specify the email server in maxView Storage Manager by IP address.

4.1.3 SGPIO Enclosures
In this release, maxView Storage Manager does not show connector information 
for SGPIO enclosures.

4.1.4 Non-RAID Mode Controllers
maxView Storage Manager can "see" RAID controllers operating in HBA mode, 
Auto-Volume mode, and Simple Volume mode (Adaptec Series 8, 
Smart Family controllers only). However, to change the controller mode on 
Adaptec Series 8 controllers, you must use ARCCONF or the BIOS. With Adaptec 
Smart-Family controllers, you can also change the controller mode with maxView 
Storage Manager.

4.1.5 Browser Issues
* To run maxView Storage Manager on the supported browsers, Javascript must be 
  enabled.
* With Ubuntu Linux, Firefox 46/47 has alignment problems in some parts of the 
  maxView GUI.
  WORKAROUND: Upgrade to Firefox 48.
* Due to a certificate bug in Firefox 31.x, maxView login may fail on RHEL 
  systems with a "Secure Connection" error. (Firefox 31.1 is the default 
  browser on RHEL 6.6; on RHEL 7.1, it is 31.4.)
  WORKAROUND: Upgrade to the latest Firefox version.
* With the default Security setting in Microsoft Internet Explorer 10 and 11, 
  you may be unable to login to maxView Storage Manager or experience certain 
  GUI display issues in the maxView online Help system.
  WORKAROUND: Change the default Security setting from High (or Medium-High) 
  to Medium. Alternative: add the GUI IP address to the trusted sites list.
* With Google Chrome, the scrollbar resets itself to the top after selecting a 
  drive in the Logical Drive wizard. To select another drive, you must scroll 
  back down to the drive location.
* With Microsoft Internet Explorer 10, the controller firmware update wizard 
  does not show the f/w update file name when the upload completes. To refresh 
  the display, click Next then Back.
* We do not recommend using multiple browsers simultaneously on the same 
  maxView instance. Doing so may cause display issues or freezes; to restore 
  maxView, refresh the display by pressing F5.

4.1.6 Remote System Access on Linux and Windows
To avoid remote system access failures from Linux and Windows clients running 
maxView Storage Manager, check and update one or all of the following system 
and network settings:

Windows:
* Ensure that the DNS server information is properly configured.
* Ensure that the system is configured with the IP address.
* Ensure that the OS hostname is according to the standard.
* Ensure that the hostname to IP address mapping is updated in the DNS. At the minimum, ensure
  that the hostname to IP mapping is entered in /etc/hosts file.

4.1.7 RAID 10 Segment Order
maxView Storage Manager and the Ctrl-A BIOS report the wrong segment order for 
RAID 10s, regardless of the order in which the drives are selected.

Example 1: Create RAID 10 with 2 SDDs and 2 HDDs in maxView Storage Manager:
(1a) ARCCONF and maxView Storage Manager see the following RAID segment order:
                Device 2 (S1)
                Device 1 (H2)
                Device 3 (S2)
                Device 0 (H1)
   
(1b) the BIOS/CTRL-A sees the following RAID segment order:
                Device 2 (S1)
                Device 1 (H2)
                Device 0 (H1)
                Device 3 (S2)
   
(1c) the correct and expected RAID segment order is:
                Device 2 (S1)
                Device 0 (H1)
                Device 3 (S2)
                Device 1 (H2)

Example 2: Create RAID 10 with 2 SDDs and 2 HDDs with ARCCONF:
(2a) the BIOS/CTRL-A sees the following RAID segment order:
                      Device 0 (H1)
                      Device 2 (S1)
                      Device 1 (H2)
                      Device 3 (S2)
  
(2b) ARCCONF and maxView Storage Manager see the correct RAID segment order:
                      Device 2 (S1)
                      Device 0 (H1)
                      Device 3 (S2)
                      Device 1 (H2)

4.1.8 RAID 10 Rebuild Order
With a degraded RAID 10 logical drive, the drive is rebuilt one leg at a time, 
not in parallel.

4.1.9 Locate Logical Drive Blink LED
In maxView Storage Manager, Locate Logical Drive continues to blink the LED 
for a pulled physical drive in the array after the locate action is stopped. 
(For unpulled drives, the blinking stops.) This issue is not seen with 
ARCCONF.

4.1.10 ARCCONF Backward Compatibility
ARCCONF is backward compatible with older Adaptec controller models. As a 
result, the ARCCONF user's guide and online help show command options that are 
not supported by newer Adaptec controllers, like the Adaptec Series 8 or later products.
Example: With ARCCONF SETMAXCACHE, Adaptec Series 8 controllers 
do not support ADDTOPOOL or REMOVEFROMPOOL.

4.1.11 Updating Hard Disk Firmware on VMware Guest OS
Updating the firmware for a SAS hard disk drive with ARCCONF/maxView can crash 
(PSOD) the VMware Guest OS. This issue is seen with SAS hard drives only; with 
SATA drives, the firmware update completes successfully.

4.1.12 Hot Swap Issues on VMware CentOS Guest OS
Due to a limitation with the VMware CentOS Guest OS network configuration, 
maxView Storage Manager does not show newly added or removed hot swap drives. 
(ARCCONF sees the configuration change but maxView does not.)
WORKAROUND: (1) reboot the system or restart maxView services; (2) adjust the 
network configuration; contact Adaptec Support for more information.

4.1.13 Enclosure Status Reporting
Enclosure status, in maxView Storage Manager, is event-driven. As a result, 
enclosures can have a "Degraded" status even if related resources (fan, 
temperature, power) are performing normally (Optimal status). For instance, 
the Enclosure status changes to "Degraded" if the system reports an "Enclosure 
device not responding ..." event, even if other sensor values are normal.

4.1.14 PHY Status on Enclosure Backplanes
In the Controller Properties window, maxView Storage Manager shows the 
Connector Info as "unknown" for all PHYs on an enclosure-based backplane (for 
instance, a backplane attached to connector 1).

4.1.15 Special Characters in Logical Device Names
Special characters are permitted in logical device names in maxView Storage 
Manager, the BIOS, and ARCCONF. However, with Linux ARCCONF (create, setname), 
special characters must be "escaped" to ensure proper interpretation. For 
example:  ARCCONF SETNAME 1 LOGICALDRIVE 1 arc_ldrive%\$12\&amp;

4.1.16 Speaker Status on SuperMicro SAS2X28 Enclosures
SuperMicro SAS2X28 enclosures do not propagate the speaker status to maxView 
Storage Manager. As a result, maxView always displays the speaker status as 
Off.

4.1.17 Broadcasting Alerts About Status and Activity
This feature is not supported by the maxView Storage Manager or ARCCONF and 
has been removed from the product documentation.

4.1.18 User-Specified Archive Path
While executing the savesupportarchive command where a user-specified path 
exists, ARCCONF will instead place the logs under the /var/log/ directory.

4.1.19 Clear Configuration Status After Re-Insertion
After removing a RAID member and then clearing the controller configuration, 
maxView Storage Manager recovers the configuration for all RAID volumes and 
physical drives when the offline drive is re-inserted and the OS restarted. By 
design, RAID members store metadata about all other virtual devices. This 
allows the controller to recover the configuration from the re-inserted drive, 
even though the configuration was previously cleared.

4.1.20 Configuration Changes in Device Manager
After disabling/enabling the Microsemi Adaptec controller in the Device 
Manager, it can take up to 10 minutes for maxView Storage Manager to detect 
the configuration change.
WORKAROUND: Use the Refresh link in the maxView GUI to update the 
configuration.

4.1.21 Online Help Issues
* Help from the Express Configuration wizard opens the Custom Configuration 
  help panel.
  WORKAROUND: Open the Express Configuration Help panel from the Help System 
  TOC pane.
* Contrary to the online help, SMR drives are not supported for RAID volumes 
  or hot spares on Smart-Family controllers
* In IE11, topics in the help may display with a 'Topics Not Found' message 
  when their corresponding links are clicked in the navigation pane of the 
  help.
  WORKAROUND: Click on the "Add" browser prompt to add certification to view 
  the content.

4.2 Limitations for Series 8 Controllers

4.2.1 RAID-Level Migrations
* The following RAID-level migrations (RLM) are supported in this release:
  * RAID 0 to RAID 5
  * RAID 0 to RAID 10
  * RAID 5 to RAID 6
  * RAID 6 to RAID 5
  * RAID 10 to RAID 5
  * RAID 5 to RAID 10
  * RAID 1 to RAID 5
  * SIMPLE VOLUME to RAID 1
  * RAID 1 to SIMPLE VOLUME
* When migrating a Simple Volume to RAID 1, maxView Storage Manager reports 
  the logical drive state as Impacted (rather than Reconfiguring); this is 
  normal.
* We do not recommend performing a RAID-level migration or Online Capacity 
  Expansion (OCE) on a logical drive with maxCache SSD caching enabled.
  NOTE: maxView Storage Manager grays out the options for logical drives with  
  maxCache enabled. ARCCONF terminates the task.
* Always allow a RAID-level migration to complete before creating a support 
  archive file. Otherwise, the support archive will include incorrect 
  partition information. Once the migration is complete, the partition 
  information will be reported correctly.

4.2.2 maxCache Device Migration
Only one maxCache Device is supported per controller. Moving the maxCache 
Device (all underlying SSDs) from one controller to another (assuming both 
controllers support maxCache) is supported only if (1) the new controller does 
not have a maxCache Device or any other maxCache Device with a conflicting 
device number and (2) only after a clean shutdown on the old controller.

4.2.3 ARCCONF maxCache Device Size Issue
ARCCONF supports >2 TB maxCache Devices if you create the device with the 'max' 
parameter. However, the functional limit for the maxCache Device is 2 TB, which 
is also the limit in maxView Storage Manager.

4.2.4 Power Management Issues
* Power management is not supported on FreeBSD.
* Capturing support logs from maxView or ARCCONF will spin up drives when 
  power management is active. This behavior is by design.
* The Logical Drive Creation wizard no longer includes the option to enable 
  power management settings.
  WORKAROUND: Enable power management for the logical drive from the Set 
  Properties window.

4.2.5 Verify/Verify with Fix
* Incremental progress percentage information in SNMP is not updated for the 
  Verify/Verify_Fix operations. Task progress shows 0% until complete, then 100%.
* In maxView Storage Manager and ARCCONF, the Verify_Fix operation is NOT 
  available when:
  1. The logical drive has a non-redundant RAID level.
  2. Other tasks are in progress on the logical drive.
  3. The logical drive is in a non-optimal or impacted state.

4.2.6 ATA Secure Erase
In ARCCONF, the ATA Secure Erase operation cannot be aborted. Once started, it 
continues to completion.
In maxView Storage Manager, the drive is locked during ATA Secure Erase. To 
recover, use the ARCCONF ATAPASSWORD CLEAR <passwd> command; the default 
password is 'pmc-sierra'.
NOTE: ATA Secure Erase is also available in the Ctrl-A BIOS.

4.2.7 Simple Volume Support
* In this release, you can create a maximum of 128 Simple Volumes in maxView 
  Storage Manager, ARCCONF, or the BIOS.
* When a Simple Volume fails, the status remains unchanged after drive 
  replacement.
  WORKAROUND: Manually delete the Simple Volume to remove it.

4.2.8 Auto-Volume Support
* Changing a controller into Auto-Volume mode (ARCCONF/BIOS) is not supported 
  if the configuration includes any logical device type other than Simple 
  Volume, including a maxCache Device. The mode switch from RAID mode to Auto-
  Volume mode is blocked if any other type of logical volume exists (including 
  maxCache). After switching to Auto-Volume mode, you can create and delete 
  Simple Volumes only in maxView Storage Manager and ARCCONF.
* In Auto-Volume mode, only the first 128 RAW drives are converted to Simple 
  Volumes; the rest of the RAW drives remain unchanged. If you uninitialize a 
  Ready drive while the controller is in Auto-Volume mode, the firmware 
  converts the drive automatically until the Simple Volume count reaches the 
  maximum.

4.2.9 Hot-Removing Disk Drives on Xenserver Guest OS
XenServer does not support "hot-removal" of disk drives from a partitioned 
logical drive. As a result, if you hot remove a disk from a logical drive, the 
Guest OS becomes inaccessible because the drive partition remains visible to 
the OS instead of being cleared.
WORKAROUND: Reboot the XenServer host, detach the failed partition, then 
restart the VM.

4.2.10 Viewing Logical Drive Details After Re-Insertion
If you remove/re-insert a RAID member when the controller's "Automatic 
Failover" property is enabled and there is no hot spare configured/protecting 
the logical device, you must click on the Refresh link in maxView Storage 
Manager to view the proper data of the re-inserted drive and RAID volume.

4.2.11 VMware ESXi 6.X CIM Service Errors
When running VMware ESXi 6.X, the CIM service becomes stuck and users cannot log in.
WORKAROUND: Disable the hhrcwrapper by following these steps:
1. esxcli system wbem set -e 0
2. esxcli system wbem provider list
3. esxcli system wbem provider set -e 0 -n vmw_hhrcwrapper
4. esxcli system wbem provider list
5. esxcli system wbem set -e 1

4.2.12 Proxy/Firewall Connection Issues
maxView uses WebSocket and server side event for notifying the logged in users instantaneously about
the changes in the configuration. Occasionally, the proxy/firewall does not allow a connection to stay
inactive for a longer period of time, and the connection usually gets closed automatically by the proxy.
SYMPTOMS: Event and changes for the operation performed through ARCCONF do not reflect in maxView
GUI.
WORKAROUND: 
* Configure the proxy/firewall to allow inactive connection to stay for up to 5 minutes (with 2017.1,
recovery has been added in the code to reestablish the closed connection).
* Use the refresh link provided in maxView GUI to get the updated configuration.

4.3. Limitations for Smart Family Controllers

4.3.1 SES Passthrough Commands to Expanders
SES passthrough commands to expanders fail.

4.3.2 Firmware Upgrade Issues
For systems using Adaptec HBA 1000 with an Adaptec SAS Expander 82885T card, 
where the ARCCONF utility is used to upgrade the expander firmware, ARCCONF 
may crash if 64-bit chunk sizes are used.
WORKAROUND: Use 32-bit chunk sizes to upgrade/downgrade the expander firmware.

4.3.3 Mount Point Information with MPIO Support
When Multipath I/O (MPIO) is enabled in Windows, mount point information is 
not available in maxView or ARCCONF.

4.3.4 Locate Physical Disk LED Behavior
Since the locate commands are executed at the physical device level, the LED 
that is used to locate physical disks in an array when using ARCCONF/maxView 
will continue to blink the physical device(s) even after deleting the array.

4.3.5 Help Button Leads to Empty Login Page
The Help Button in Controller Properties > Cache does not populate the Help Page as expected. Instead, an empty Login Page is shown.

4.3.6 Firefox Browser Crashes While Uploading Firmware
Uploading the firmware build (luxor.bin) file while using Firefox version 52.xxx can cause the browser to crash.
WORKAROUND: Upgrade to Firefox version 55.0.3 to resolve this issue.

4.3.7 Backspace Recognized as Input Character
In Linux operating systems, the backspace and delete keys are considered input characters when the
user tries to input maxCrypto crypto/user password using the prompt option.
WORKAROUND: Ensure that password string does not contain backspaces or other special characters
like delete, escape, function, page up, page down, or home keys.

4.3.8 maxView Login Page Not Displayed After maxView Repair
The maxView login page does not load after a maxView repair. The maxView installer repair option
cannot repair when the configuration files are missing.

4.3.9 VMware SFCB CIMMOM Causes Slowdown
In ESXi 6.0 U3, the user may experience a slow response in maxView and ARCCONF operations due to
the known issue with VMware SFCB CIMMOM.

4.3.10 Remote ARCCONF Command Delays
Remote ARCCONF romupdate command takes longer to complete than the local ARCCONF. The delay
is due to the file transfer between the remote ARCCONF and the hypervisor over the network.

4.3.11 Locked ESXi User Account
In ESXi Guest OS maxView, entering a wrong password for the ESXi hypervisor during installation may
lock the ESXi user account. In this scenario, maxView login will fail even if the correct password is updated
using changevmcredential utility.
WORKAROUND 1: Execute pam_tally2 --user root reset command in ESXi hypervisor to unlock
the account.
WORKAROUND 2: Reboot the ESXi hypervisor to unlock the account.

4.3.12 Browser Automatically Fills Username and Password Fields
Browsers can automatically fill the username and password fields.
WORKAROUND: Disable the password manager and autofill forms in the browser settings.

4.3.13 Expanded Logical Devices Not Initiated by Firmware
maxView/ARCCONF allows you to expand a logical device to the approximate same size, but the expansion
will not be initiated by the firmware. This is because the actual size of the logical device will be always
less than the requested size due to the logical device metadata storage requirement.

--------------------------------------------------------------------

Copyright (c) 2018 Microsemi Corporation. All rights reserved. Microsemi and 
the Microsemi logo are trademarks of Microsemi Corporation. All other 
trademarks and service marks are the property of their respective owners.

Microsemi Corporation (Nasdaq: MSCC) offers a comprehensive portfolio of 
semiconductor and system solutions for communications, defense and security, 
aerospace, and industrial markets. Products include high-performance and 
radiation-hardened analog mixed-signal integrated circuits, FPGAs, SoCs, and 
ASICs; power management products; timing and synchronization devices and 
precise time solutions; voice processing devices; RF solutions; discrete 
components; enterprise storage and communications solutions; security 
technologies and scalable anti-tamper products; Ethernet solutions; Power-
over-Ethernet ICs and midspans; custom design capabilities and services. 
Microsemi is headquartered in Aliso Viejo, California and has approximately 
4,800 employees world-wide. Learn more at www.microsemi.com.

PMC-2153191, Issue 7

Microsemi makes no warranty, representation, or guarantee regarding the 
information contained herein or the suitability of its products and services 
for any particular purpose, nor does Microsemi assume any liability whatsoever 
arising out of the application or use of any product or circuit. The products 
sold hereunder and any other products sold by Microsemi have been subject to 
limited testing and should not be used in conjunction with mission-critical 
equipment or applications. Any performance specific ations are believed to be 
reliable but are not verified, and Buyer must conduct and complete all 
performance and other testing of the products, alone and together with, or 
installed in, any end-products. Buyer shall not rely on any data and 
performance specifications or parameters provided by Microsemi. It is the 
Buyer's responsibility to independently determine suitability of any products 
and to test and verify the same. The information provided by Microsemi 
hereunder is provided "as is, where is" and with all faults, and the entire 
risk associated with such information is entirely with the Buyer. Microsemi 
does not grant, explicitly or implicitly, to any party any patent rights, 
licenses, or any other IP rights, whether with regard to such information 
itself or anything described by such information. Information provided in this 
document is proprietary to Microsemi, and Microsemi reserves the right to make 
any changes to the information in this document or to any products and 
services at any time without notice.

The technology discussed in this document may be protected by one or more 
patent grants.